<h2 style="margin: 10pt 0cm 0pt"><font size="3" color="#990000">Fireplace design – A Real Burning Issue..</font></h2><p style="margin: 10pt 0cm 0pt"> </p><p><span style="font-size: 10pt; line-height: 200%; font-family: ‘Verdana’,’sans-serif’; letter-spacing: 1pt">Mantlepiece and grate styles have altered but the basic structural elements of a fireplace have not radically changed for hundreds of years. The early combination of a large stone or brick opening with a chimney built over it evolved from the obvious fact that smoke rises, rather than from a scientific understanding of how a well-designed flue system works. Consequently early wood and later coal-burning fires were very inefficient and it was not until a certain Benjamin Thompson (also known as Count Rumford) produced his thesis on the principles of fireplace design in 1799 that smaller grates and improvements in the internal shape of the openings were introduced.</span></p><span style="font-size: 10pt; line-height: 200%; font-family: ‘Verdana’,’sans-serif’; letter-spacing: 1pt"><p style="margin: 0cm 0cm 0pt" class="MsoNormal">A brick or stone enclosure forms the basis of the fireplace. Variously known as the fireplace opening or recess or builders opening, it may be set flush with the wall or built out into the room, forming a chimney breast. This chimney breast rises through the height of the house, emerging through the roof to form a chimney stack. At the top of the opening the gather and flue combine to carry the smoke up the chimney. If the chimney is shared by several fireplaces on different floors, it may contain more than one flue.</p> <p style="margin: 0cm 0cm 0pt" class="MsoNormal">The masonry over the fireplace opening is supported by a lintel or a brick arch. Old inglenook fireplaces used massive oak beams, whereas a strong iron strap usually supports an early brick arch. Later fireplaces may have a straight arch supported by angle iron, and by the twentieth century cast concrete lintels were the norm. </p> <p style="margin: 0cm 0cm 0pt" class="MsoNormal">A hearth, constructed from non-combustible materials such as stone or tile-faced concrete, projects out into the room to protect the floor from falling ashes. In most old houses the hearth was set flush with the floor, although sometimes a superimposed one was used to raise the level. The space within the fireplace opening, known as the back hearth, is usually level with the hearth itself. A dog grate for burning wood or coal can be placed on this back hearth. However, by the mid-nineteenth century the mass produced cast-iron register grate which filled the opening, had become the fashion. </p> <p style="margin: 0cm 0cm 0pt" class="MsoNormal">To complete the assembly, a mantelpiece or mantel – or fireplace surround, as it is often called today – is fitted to frame the grate or fireplace opening. The mantel may be constructed from stone, slate, marble, wood or cast iron. The walls around it may be finished with wood paneling, or more commonly with plaster, and in some cases the mantel extends upwards to form an impressive chimneypiece. Mirrored overmantels were introduced in the late eighteenth century, and these became the classic feature of Victorian sitting rooms. </p> <p style="margin: 0cm 0cm 0pt" class="MsoNormal">Within this fireplace an open fire burning wood or coal is a cheerful sight, but if it is your only source of heat, as it was for centuries, this romantic image can soon fade especially if the fire does not burn properly. Getting a fire started and keeping it alight then becomes a challenge, if not a chore. For wood and coal fires to burn well a good supply of air is needed under the grate, as well as a means of escape for the hot gases and smoke. With the fuel safely contained within the fireplace opening on a grate, free circulation of air is possible and waste ash can fall through the grate so the fire is not stifled. If the chimney is inadequate or the flow of air is restricted the fire will not function effectively. </p> <strong>About the Author<span style="font-size: 16.5pt; line-height: 200%; font-family: ‘Arial’,’sans-serif’"></span></strong> <p style="margin: 0cm 0cm 0pt" class="MsoNormal"><span style="font-size: 10pt; line-height: 200%; font-family: ‘Verdana’,’sans-serif’; letter-spacing: 1pt">Richard Banks is a contractor with many years experience in home remodelling and improvements. For more information on fireplaces visit <a href="http://www.fireplacecapital.com/" target="_blank"><span style="font-size: 9pt; line-height: 200%; font-family: ‘Tahoma’,’sans-serif’"><font color="#800080">Fireplace Capital</font></span></a><br /><br />Source: <a href="http://www.articlestree.com/tags/home-repair.html" target="_blank"><span style="font-size: 9pt; line-height: 200%; font-family: ‘Tahoma’,’sans-serif’"><font color="#800080">Home Repair Articles</font></span></a> on ArticlesTree.com</span></p></span>
Recent Posts
Archives
- November 2015
- October 2015
- May 2015
- April 2015
- March 2015
- February 2015
- January 2015
- December 2014
- November 2014
- October 2014
- September 2014
- August 2014
- July 2014
- June 2014
- May 2014
- April 2014
- March 2014
- February 2014
- January 2014
- December 2013
- November 2013
- October 2013
- September 2013
- August 2013
- July 2013
- June 2013
- May 2013
- April 2013
- March 2013
- February 2013
- January 2013
- December 2012
- November 2012
- October 2012
- September 2012
- August 2012
- July 2012
- June 2012
- May 2012
- April 2012
- March 2012
- February 2012
- January 2012
- December 2011
- November 2011
- October 2011
- September 2011
- August 2011
- July 2011
- June 2011
- May 2011
- April 2011
- March 2011
- February 2011
- January 2011
- December 2010
- November 2010
- October 2010
- September 2010
- August 2010
- July 2010
- June 2010
- May 2010
- April 2010
- March 2010
- February 2010
- January 2010
- December 2009
- November 2009
- October 2009
- September 2009
- August 2009
- July 2009
- June 2009
- May 2009
- April 2009
- March 2009
- February 2009
- January 2009
- December 2008
- November 2008
- October 2008
- September 2008
- August 2008
- July 2008
Recent Comments